Atmospheric parameter sensors are advanced devices designed to monitor and measure a variety of atmospheric parameters. Intelligent sensors are designed for precise control of environmental conditions, including temperature, humidity, atmospheric pressure, gas concentrations, and other important parameters.

Description

The atmospheric parameter sensor for continuous measurement of gas content in the air is an advanced device that provides accurate measurements, a short response time, and multiplexed digital signal outputs. Additionally, it is compatible with various data transmission standards, making it easy to integrate with different control and monitoring systems. It is an ideal tool for monitoring and controlling air quality in various applications such as environmental protection, industrial safety, or indoor air quality monitoring. Due to its accuracy and flexible communication options, it can easily be integrated into existing monitoring and control systems.

Key Features of the Atmospheric Parameter Sensor

Continuous Measurement: The sensor provides continuous measurement of gas content in the air, enabling real-time air quality monitoring in a given environment.

High Accuracy: With advanced measurement technologies, the sensor ensures high measurement accuracy, which is crucial for monitoring toxic substances or other important atmospheric parameters.

Short Response Time: The sensor features a short response time, meaning it can detect changes in atmospheric parameters in real-time, allowing for a quick response in hazardous situations.

Two Digital Signal Outputs: The sensor comes with two digital signal outputs that can be configured for various purposes. These can be used to transmit measurement data to monitoring systems or as cut-off signals for power sources in case of failure or when preset limit values are exceeded.

Transmission Standards: The sensor is compatible with various data transmission standards, simplifying its integration with different systems.

Supports: V23 FSK modem, enabling data transmission via frequency modulation. The output voltage range of 0.4 – 2 V allows adjustment of the signal to the receiver’s needs. RS 485 is a reliable industrial communication standard for long-distance data transmission. A frequency range of 5 – 15 Hz provides flexibility to adjust the measurement frequency as needed.

Specification

Optical signaling: Optical indicator mounted on the housing; LED indicators in the display window.
KB-1 Keyboard: Calibration, setting adjustments, and operation mode change for the sensors; Protection against unauthorized changes; Operation mode indicated by LED diodes; Power supply from the cooperating device.
Measurement Head: Option for external measurement head; Connection cable up to 30 meters.
Explosion-proof Construction Feature:I M 1 Ex ia I, II 2G Ex ia II (CH4); Devices compliant with the requirements of: Directive 94/9/EC (ATEX) and Regulation MG of December 22, 2005, on essential requirements for protective equipment and systems.

Additional Information

Alarm Thresholds: Possibility to set four independent alarm thresholds; Information about alarm thresholds; LCD display; LED signaling diode; Report to the dispatch system.
Alarm Threshold Settings: Setting alarm threshold values; Assigning thresholds to one or both of the binary outputs.
Safety: Settings only from the gas system dispatch level.

Product Range
NameDescriptionMeasurement RangeTransmission Standard
DCHMethane sensor0 ÷ 100% CH4V23 FSK modem; 0,4 ÷ 2V; 4 ÷ 20mA;
DCH IRMethane sensor (IR) 0 ÷ 100% CH4V23 FSK modem; 0,4 ÷ 2V; 4 ÷ 20mA;
DCD IRCarbon dioxide sensor (IR)0 ÷ 5% CO2V23 FSK modem; 0,4 ÷ 2V; 4 ÷ 20mA;
DCOCarbon monoxide sensor 0 ÷ 1000 ppm COV23 FSK modem; 0,4 ÷ 2V; 4 ÷ 20mA;
DOXOxygen sensor0 ÷ 25% O2V23 FSK modem; 0,4 ÷ 2V; 4 ÷ 20mA;
DHTHumidity, temperature, and pressure sensorCiśnienie atmosferyczne: 800 ÷ 1200 hPa
Temperatura: -10 °C ÷ 40 °C
Wilgotność: 0 ÷ 95% RH
V23 FSK modem; 0,4 ÷ 2V; 4 ÷ 20mA;
DRCDifferential pressure sensor±1000 Pa; ± 2000 Pa; ± 5000 Pa; ± 10 000 Pa; ±20000 Pa V23 FSK modem; 0,4 ÷ 2V; 4 ÷ 20mA;
DPTAbsolute pressure, humidity, and temperature sensor Ciśnienie atmosferyczne: 800 ÷ 1300 hPa
Temperatura: -10 °C ÷ 40 °C
Wilgotność: 0 ÷ 95% RH
V23 FSK modem
DNDNitrogen dioxide sensor0 – 20 ppm NO2V23 FSK modem; 0,4 ÷ 2V; 4 ÷ 20mA;
DHSHydrogen sulfide sensor0 – 100 ppm H2SV23 FSK modem; 0,4 ÷ 2V; 4 ÷ 20mA;
DAVAnemometer-20  ÷  20 m/sV23 FSK modem; 0,4 ÷ 2V; 4 ÷ 20mA;
Ex Zone

The device is designed for use in explosive atmospheres. It is intended for underground use in mines and in surface areas of mines at risk of gas or dust explosions. Group I Category M1 – Equipment intended for mining enterprises exposed to methane and coal dust, ensuring a very high level of safety with two independent safety measures.